Page Precaution Of Laying Wires Super Free Match Service Manual The electric installation should be carried out by the professional as instructed by the local laws, regulations and also this manual. The air switch coupled with the leakage current protection switch must be equipped in the circuits, which is of enough capacity and of both magnetic and thermal tripping functions in case of the short circuit and overload.
Fix each ground wire separately with the ground screw. If the connecting wire is connected to the terminal incorrectly, the unit will not work normally. If the transmission line need to be connected to the other BU module, please connect the extra line to the N 1 , 2 terminals with the sign of BU. Reassemble the electrical box cover.
Recover the surface panel. The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
It is not allowed to use aluminum plastic composite pipe. Page Super Free Match Service Manual if the drainage is smooth; on another hand, check the piping system for any leakage.
Steel sheath shall be provided to the pipe crossing the wall or slab. The pipe joint shall not be positioned within the sheath. Page Super Free Match Service Manual matter how forcible it pushes, but there is no flowing water, thus resulting in abnormal water level. This will cause flooding of the ceiling. During cooling, the moisture in the air will condense on the surface of evaporator. Such condensing water must be drained out of the unit. Meanwhile, the drainage pipe has an important role to determine if the air conditioner can plays its full functions.
Do not use the foam on the branch pipe as the material for heat insulation. It has several following advantages: Automatically detect indoor unit numbers Automatically assign indoor unit addresses Automatically display real running function and error code Option settings to suit the demand of the customer 1.
The first-level menu includes control unit and display unit. Page Check Before Contacting Maintenance Serviceman Do not repair the air conditioner personally but instead contact the professionally skilled personnel at the GREE appointed service center, as the incorrect repair would cause electric shock or fire hazard etc.
Page Error Description Super Free Match Service Manual Conditions Causes When restart the unit soon after it The overload protection switch of the unit let the The unit does not run is stopped startup delayed for three minutes As soon as power supply is on The unit will stand by for approximate one minute The unit blows out mist When the cooling operation starts Page Malfunction Display: High Pressure Protection Super Free Match Service Manual Service personnel shall collect the malfunction information as much as possible and research them thoroughly, list these electrical parts which may cause malfunction, service personnel shall be able to determine the specific reason and solve the faulted parts.
Observe the status of the complete device and do not observe the partial. Page Super Free Match Service Manual Low pressure protection Replace the outdoor unit mainboard Check the Check the pressure with a manometer: low pressure sensor: is Replace the low pressure sensor is it really low?
Check Charge refrigerant according to the amount specified in the refrigerant in the system: is it nameplate and calculated additional amount sufficient? Replace relevant discharge temperature sensor Are the Replace relevant electronic Check the Check the orientation of plug transmission line between outdoor unit and BU module: is it properly and socet connected? Check the Check the Maintain the cables of water Measure the DC voltage value between black Replace the pressure line and green line of the sensor: is it sensor Resistance Voltage Voltage Temp.
Steps Illustrations Operation Instructions Disconnect the left left side plate and rear side side plate and rear side plate; plate Remove left side plate and rear side plate. Loose the fixed Unscrew the fixed screws of the screw of the compressor compressor base base Remove and replace the compressor. Remove the Note: never let the flame compressor away contact any other from the seating component during the replacement. Solder the pipe to make them pipeline with the connected suction and Note: never let the discharge ports of flame contact any other the compressor component.
Tighten the fixing screw of the power cord. Steps Illustrations Operation Instructions a Unscrew the fixed screws of the magnet 1. Remove the magnet Steps Illustrations Operation Instructions Open the cover plate of the 1. All search results are from google search results. Please respect the publisher and the author for their creations if their books are copyrighted. Yu need to follow the Same process to switch off the ac.
Ecovacs Deebot Robots Vacuum Cleaner review, price and unboxing. How to change Fahrenheit to Celsius in Voltas ac remote. Voltas split ac remote control function guide, manual setting, price - tata voltas original ac remote operation. Post a Comment. Home Product Reviews Voltas split ac remote control function guide, manual setting, price - tata voltas original ac remote operation. Share This Facebook Twitter. No comments:. Subscribe to: Post Comments Atom. As constant endeavor to expand our footprint in the market the new Brand shop, Narayan House.
Window a. AR; Go. Split ac 1.